Tuam Tshoj pheej yig tus nqi Techfine Fais fab mov 650va Kab Sib tham sib UPS rau Tsev Khoos phis tawj Offline UPS
Txhua yam peb ua yog ib txwm muaj feem xyuam nrog peb txoj cai "Cov neeg siv khoom ua ntej, Muaj kev ntseeg siab hauv 1st, mob siab rau kev ntim khoom noj thiab kev tiv thaiv ib puag ncig rau Tuam Tshoj Tus nqi pheej yig Techfine Power Supply 650va Kab Sib Tham UPS rau Tsev Khoos phis tawj Offline UPS, Peb lub tuam txhab mob siab rau ua ntej rau kev teeb tsa nce mus sij hawm ntev thiab qab ntxiag kev lag luam me koom tes nrog cov neeg siv khoom thiab cov neeg lag luam los ntawm txhua qhov chaw hauv ntiaj teb.
Txhua yam peb ua yog ib txwm muaj feem cuam tshuam nrog peb txoj cai "Client ua ntej, Muaj kev ntseeg siab hauv 1st, mob siab rau kev ntim khoom noj thiab kev tiv thaiv ib puag ncig rauTuam Tshoj UPS thiab Lag Luam Lag Luam Thoob Ntiaj Teb , Peb ntseeg hais tias nrog peb cov kev pabcuam zoo heev uas koj tuaj yeem tau txais kev ua haujlwm zoo tshaj plaws thiab raug nqi tsawg kawg nkaus los ntawm peb lub sijhawm ntev. Peb cog lus los muab cov kev pabcuam zoo dua thiab tsim kom muaj txiaj ntsig ntxiv rau txhua tus neeg siv khoom. Cia siab tias peb tuaj yeem tsim lub neej yav tom ntej zoo ua ke.
Nta
Lus Qhia me me
1. Nyob rau lub sijhawm lav lub tshuab muaj teeb meem, thov hu rau cov neeg ua haujlwm muag khoom, peb yuav ua lub luag haujlwm rau cov neeg siv khoom.
2. Tshaj li lub sijhawm lav, kev ua haujlwm tsis raug thiab kev puas tsuaj rau tib neeg, peb tseem yuav muab kev pabcuam thiab kev txhawb nqa, peb yuav muab cov khoom seem ntawm tus nqi.
3. Raws li tus neeg siv khoom xav tau, peb tuaj yeem muab qhov tsis sib xws, tab sis tus nqi yuav yog me ntsis siab dua li cov tshuab tsoos.
Daim ntawv thov
Cov ntaub ntawv ua chaw, Lub party system, Computer servers, Kev kho mob, tsheb, hluav taws xob, IT, Industrial thiab lwm yam lag luam.
Factory Production Line
Ntim
Txhua yam peb ua yog ib txwm muaj feem xyuam nrog peb txoj cai "Cov neeg siv khoom ua ntej, Muaj kev ntseeg siab hauv 1st, mob siab rau kev ntim khoom noj thiab kev tiv thaiv ib puag ncig rau Tuam Tshoj Tus nqi pheej yig Techfine Power Supply 650va Kab Sib Tham UPS rau Tsev Khoos phis tawj Offline UPS, Peb lub tuam txhab mob siab rau ua ntej rau kev teeb tsa nce mus sij hawm ntev thiab qab ntxiag kev lag luam me koom tes nrog cov neeg siv khoom thiab cov neeg lag luam los ntawm txhua qhov chaw hauv ntiaj teb.
Tuam Tshoj pheej yig tus nqiTuam Tshoj UPS thiab Lag Luam Lag Luam Thoob Ntiaj Teb , Peb ntseeg hais tias nrog peb cov kev pabcuam zoo heev uas koj tuaj yeem tau txais kev ua haujlwm zoo tshaj plaws thiab raug nqi tsawg kawg nkaus los ntawm peb lub sijhawm ntev. Peb cog lus los muab cov kev pabcuam zoo dua thiab tsim kom muaj txiaj ntsig ntxiv rau txhua tus neeg siv khoom. Cia siab tias peb tuaj yeem tsim lub neej yav tom ntej zoo ua ke.
Qauv | BNT990-M | BNT9150/180-M | BNT9300-M | |
Rated Peev Xwm | Txee Capacity | 20-90 kVA / 20-90 kW | 25-150kVA / 25-150kW 30-180kVA / 30-180kW Lub cev muaj zog | 30-300kVA / 30-300kW Cov |
Ib Ppwer Module Capacity | 20kVA/20kW, 25kVA/25kW, 30kVA/30kW | |||
MAX. Lub zog Module NO. | 3 | 5/6 | 10 | |
NPAJ | ||||
Main tswv yim | Nominal voltage (Vac) | 380/400/415 | ||
Voltage Range (Vac) | 138 ~ 485Vac; 305 ~ 485Vac load, 138 ~ 305Vac load | |||
Theem | 3-theem hauv / 3-theem tawm | |||
Nominal zaus (Hz) | 40-70 : kuv | |||
Hwj chim Factor | ≥0.99 | |||
Harmonic Distortion (THDi) | ≤3% (100% load) | |||
Bypass Input | Nominal voltage (Vac) | 380/400/415 | ||
Voltage Range (Vac) | 220 Vac: 25% (+ 10%, + 15%, + 20%) | |||
230 Vac: 20% (+ 10%, + 15%) | ||||
240 Vac: 15% (+ 10%); -45% (-10%, -20%, -30%) | ||||
Theem | 3-theem hauv / 3-theem tawm | |||
Lub zog taug kev hauv | YOG | |||
Bypass Back Irrigation | YOG | |||
Generator Access | YOG | |||
OUTPUT | ||||
Qhov voltage (Vac) | 380/400/415 ± 1% | |||
Fais fab xwm txheej | 1 | |||
Ntau zaus (Hz) | AC hom | ± 1% / ± 2% / ± 4% / ± 5% / ± 10% | ||
Roj teeb hom | (50/60 ± 0.1%) Hz | |||
Waveform | Ntshiab Sinewave | |||
Admissible Crest Factor | 3:01 ib | |||
Harmonic Distortion (THDV) | ≤2% (100% Tawm Tawm); ≤3% (100% Tsis-linear Load) | |||
Hloov Sijhawm (ms) | 0 | |||
Kev ua tau zoo (%) | 95.50% | |||
Muaj peev xwm tshaj | 1 teev rau 110%, 10 mins rau 125%, 1 min rau 150%, 200ms rau> 150% | |||
Roj teeb | ||||
Maximum Charging Tam sim no (A) | 18 | |||
Nominal voltage | ± 180V / ± 192V / ± 204V / ± 216V / ± 228V / ± 240 / ± 252 / ± 264 / ± 276 / ± 288 / ± 300Vdc | |||
(30/32/34/36/38/40/42/44/46/48/50 pcs) | ||||
Ib puag ncig | ||||
Ua haujlwm kub | 0 ℃ ~ 40 ℃ | |||
Cia Kub | -25 ℃ ~ 55 ℃ | |||
txheeb ze humidity | 0 ~ 95% | |||
Qhov siab | ||||
Lub suab nrov (dB) | ||||
PHEM | ||||
Dimension (D x W x H) mm | UPS txee | 600 × 850 × 1350 hli | 600 × 850 × 1350 600 × 850 × 1550 | 600 × 850 × 2000 hli |
Module | 440 × 620 × 86 | |||
Net Nyhav (kg) | UPS txee | 140 | 155/170 ib | 290 |
Module | nees nkaum ib |